RS-IBPSCx Solid State Catheter, Invasive BP System

This solid state invasive blood pressure system, is designed for measuring invasive blood pressure in small and large animals, such as: mice, rats, squirrels, prairie dogs, porcupines, beavers, guinea pigs, hamsters, rabbits, hares, pigs, sheep, dogs, cows, etc.

SKU RS-IBPSCX Categories , Tags ,

These 1.6F catheter-tipped solid-state pressure catheters are recommended for measuring pressure in small vessels as well as ventricular pressures in  rodents. They are also highly recommended for recording arterial and chamber pressures in large animals.  Systems include catheters, an amplifier/signal conditioner, data recorder and software.

Upto 4 catheters can be plugged directly into the IX-RA-834. Using the IA-400D additional 4 catheters can be added to the system.

Advantages:

  • High frequency response, making it the most sensitive and precise method for the monitoring of arterial pressure and for analysis of changes in the phasic arterial pressure waveform.
  • Superior sensitivity and temporal resolution compared to fluid-filled catheters make them more suitable for measuring intra-cardiac pressures from animal species with high intrinsic heart rates.
  • Unlike the fluid filled catheters, solid state catheters do not require flushing and do not have the problem of decreasing signal intensity with increasing catheter length.
  • Suitable for Rats and larger animal

Fluid Filled System

RS-IBP4
$
  • LabScribe Software
  • Blood Pressure Analysis
  • Up to 8 Channels of BP
  • Mice
  • Rats and Larger
  • Optional ECG, EMG
  • No Flushing Required
  • High Frequency Response

Solid State System

RS-IBPSCx
$$
  • LabScribe Software
  • Blood Pressure Analysis
  • Up to 8 Channels of BP
  • Mice
  • Rats and Larger
  • Optional ECG, EMG
  • No Flushing Required
  • High Frequency Response

Fiber Optic System

RS-IBPFOx
$$
  • LabScribe Software
  • Blood Pressure Analysis
  • Up to 8 Channels of BP
  • Mice
  • Rats and Larger
  • Optional ECG, EMG
  • No Flushing Required
  • High Frequency Response

Expandable System

RS-IBPF0x-RA
$$$
  • LabScribe Software
  • Blood Pressure Analysis
  • Up to 8 Channels of BP
  • Mice
  • Rat and Larger
  • Optional ECG, EMG
  • No Flushing Required
  • High Frequency Response

Join Our Community

Join the rapidly growing community of professors, teaching assistants and students in colleges and universities around the world who are using iWorx solutions to advance the science of physiology.

We are pleased to note that more than 90 of the top 100 schools in the U.S. (as ranked by US News and World Report) are currently using iWorx equipment and software in their labs.

Meet With Us

Quick online consultation with an Applications Specialist

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Invasive BP : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type

Recover Password

We will contact you with your login info. 

Newsletter Signup