RS-BIO-LA Large Animal ECG/EMG System

The RS-BIO-LA system is optimized for measuring ECG/EMG from Humans and other Large Animals.  It is available in 4 and 8 channel version

SKU RS-BIO-LA Categories , Tags , ,

The IX-BIO is a available as a 4 or 8 Channel Biopotential Amplifier that allows multiple channels of EMG, ECG, EOG to be recorded simultaneously from a single subject. The recorder is furnished with LabScribe Recording and Analysis Software and connects directly to a USB port on either a Macintosh or Windows PC.

ECG signals can be measured with the IX-BIOx.  Measuring 2 channels of ECG, Lead I and Lead II allows LabScribe software to calculate Lead III, aVR, aVF and aVL .

EMG signals can be measured at the same time as the ECG signals.

ECG

Templates for Different Species

  • Human
  • Small Dog
  • Large Dog
  • Pig
  • Rabbit
  • Guinea Pig
  • Mouse
  • Rat
  • Zebrafish 

Measurements

  • Measure various intervals such as: QRS, QT, QTc, QR, ST Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R
  • Amplitudes such as: P , Q, R, S , T, ST elevation, QR Amp

Filtering and Averaging

Use FIR and Notch filters to filer out the noise from the ECG signal before processing. 

Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval.

Graphical Display of Detected Points

The following locations are displayed on the ECG waveform:

  • Beginning, peak and end of P
  • Beginning of Q
  • peak of R wave
  • End of S
  • Beginning, peak and end of T wave

Outliers and Artifacts

Outlier removal based on abnormal R-R intervals, heart rate, noise,  activity, P amplitude, and T amplitude.

Manually mark outliers if needed.  A list of outliers is displayed

EMG

 

Measurements

Analysis

  • Time Domain Analysis
    • Rectified EMG Data
    • RMS ( Root Mean Square)
    • Envelope EMG Data
    • Filtering
    • Mean Frequency
    • Area Under The Curve

Citations

659

ECG and EMG papers on Google Scholar cite iWorx | Papers about ECG using iWorx systems on Google Scholar | Papers about EMG using iWorx systems on Google Scholar

Citations for IX-BIO4 and IX-BIO8:

LabScribe ECG Analysis Module

The iWorx LabScribe ECG Analysis Module is an add-on to LabScribe software intended to automate the analysis of ECG data from a variety of species.

Features:

  • Measure R-R, PR, QT, QR and QTc intervals, QRS, T, P and TP durations, P, Q, R, S, T amplitudes and ST elevation, etc…
  • Specific analysis templates are included to accurately delineate PQRST onset, durations and amplitudes
  • Custom templates can also be created based on unique ECG profiles and saved to a library for future use
  • Beat averaging and classification
  • Outlier removal based on abnormal R-R intervals, heart rate, noise and activity
  • Easily extract source data and average data as images or text files
  • Plug and play compatible with all iWorx data acquisition
  • Conduct arrhythmia analysis

Features

  • Measure R-R, PR, QT, QR and QTc intervals, QRS, T, P and TP durations, P, Q, R, S, T amplitudes and ST elevation, etc.
  • Specific analysis templates are included to accurately delineate PQRST onset, durations and amplitudes
  • Custom templates can also be created based on unique ECG profiles and saved to a library for future use
  • Beat averaging and classification
  • Outlier removal based on abnormal R-R intervals, heart rate, noise and activity
  • Easily extract source data and average data as images or text files
  • Plug and play compatible with all iWorx data acquisition
  • Conduct arrhythmia analysis

IX-BIO Specifications

Analog Inputs4 Biopotential ( IX-BIO4)
8 Biopotential ( IX-BIO8)
Input Range2400mV, 1200mV, 800mV, 400mV, 200mV, 100mV, 50mV, 25mV, 12mV
A/D Converter
Sampling Speed20k Samples/sec per channel simultaneous
Resolution16 Bit
System noise< 6 µV
InterfaceUSB
General
EnclosurePlastic
PowerUSB
Warranty and UpgradesProtected by a 3 year warranty

Join Our Community

See why 93 of the top 100 schools in the U.S. (as ranked by US News and World Report) are currently using iWorx equipment and software in their labs.

Join Our Community

Join the rapidly growing community of professors, teaching assistants and students in colleges and universities around the world who are using iWorx solutions to advance the science of physiology.

We are pleased to note that more than 90 of the top 100 schools in the U.S. (as ranked by US News and World Report) are currently using iWorx equipment and software in their labs.

Schedule a Demonstration

Quick online consultation with an Applications Specialist

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type

Recover Password

We will contact you with your login info. 

iWorx Newsletter Signup

By subscribing, you agree with our Privacy Policy and provide consent to receive updates from our company.