The SI-200 is a high voltage, isolated stimulator designed to deliver safe, transcutaneous stimulus pulses to a nerve or a muscle being studied.
$1,300.00
Manual: SI-200
The design of the SI-200 permits the desired current of the stimulus pulse to be generated despite the impedance on the path that the current follows. The SI-200 adjusts the voltage needed to maintain that current automatically by increasing the voltage that drives the current up to a maximum of 150 volts. Because of this capability, the SI-200 is categorized as a constant current stimulator. However, the current output of the SI-200 is limited to a maximum of 20 milliamperes, with a maximum duration of 10 milliseconds and a maximum frequency of 5000Hz.
| Specifications | |
|---|---|
| Output Current | 0-20 mA |
| Compliance Voltage | 100V |
| Isolation | Rated to 5300V RMS |
| Power | 9-15VAC/VDC 1000mA |
| Tigger Input | External TTL signal |
| Frequency Range | Externally Driven 0.1-50 Hz |
| Pulse Width Minimum | 100 µS |
| Pulse Width Maximum | 100 mS |
| Coupling Capacitance | 62pF |
The design of the SI-200 permits the desired current of the stimulus pulse to be generated despite the impedance on the path that the current follows. The SI-200 adjusts the voltage needed to maintain that current automatically by increasing the voltage that drives the current up to a maximum of 150 volts. Because of this capability, the SI-200 is categorized as a constant current stimulator. However, the current output of the SI-200 is limited to a maximum of 20 milliamperes, with a maximum duration of 10 milliseconds and a maximum frequency of 5000Hz.
| Specifications | |
|---|---|
| Output Current | 0-20 mA |
| Compliance Voltage | 100V |
| Isolation | Rated to 5300V RMS |
| Power | 9-15VAC/VDC 1000mA |
| Trigger Input: | External TTL signal |
| Frequency Range | Externally Driven 0.1-50 Hz |
| Pulse Width Minimum | 100 µS |
| Pulse Width Maximum | 100 mS |
| Coupling Capacitance | 62pF |

Stimulator Cable - Set 2 (Red and Black) Safety Connector to Snap-Lead

Set of Two Platinum Subdermal Electrodes with High Voltage Safety Connectors

Stimulator Cable - Set 2 (Red and Black) Safety Connector to Alligator

Stimulator Cable - Set 2 (Red and Black) Safety Connector to 2mm Male Pin

Stimulator Cable - Set 2 (Red and Black) High Voltage Safety Connector to Bar Electrode

Stimulator Cable for the Tissue Bath hook: TB-HS-100
![]() | ![]() | |||
| Product | Stimulus Isolator (SI-200) | 4-Channel 50V Stimulator (HCS-100) | ||
| Output Type | Constant Current (CC) device | Voltage-based device (up to 50V) | ||
| Capacity | Max 20 mA | Up to 800 mA | ||
| Channels | Single-channel isolator | 4 independent channels | ||
| Best For | Precise nerve or tissue stimulation where current stability is key | Field stimulation, large tissue samples, or multiple bath setups | ||
| Learn More | Learn More |
The iWorx team is here to help—whether you have a quick question or need hands-on support. Our technical specialists offer one-on-one assistance with setup, troubleshooting, and optimizing your system.
We will contact you with your login info.
By subscribing, you agree with our Privacy Policy and provide consent to receive updates from our company.