Search
Generic filters

LabScribe Metabolic Analysis

The LabScribe Metabolic Module is a standard module that is included with LabScribe. LabScribe automates and streamlines both the analysis and reporting of metabolic parameters from a test subject. The calculations are derived from the input data acquired during a test which would typically include oxygen and carbon dioxide concentrations, lung volumes, and heart rates.

SKU LS-METABOLIC-ANALYSIS Category

LabScribe automates and streamlines both the analysis and reporting of metabolic parameters from a test subject. The calculations are derived from the input data acquired during a test which would typically include oxygen and carbon dioxide concentrations, lung volumes, and heart rates. Raw data can be viewed in real-time within the LabScribe Main window.

Measure:

  • Relative and absolute oxygen consumption (VO2)
  • Relative and absolute carbon dioxide production (VCO2)
  • Respiratory Exchange Ratio (RER)
  • Ventilatory Equivalent (VE/VO2)
  • Expired Minute Ventilation (VE)
  • Metabolic Equivalent (METS) and more

Setup

Streamlined setup and calibration reduces error and saves time.

Setup and save a subject profile while performing a fitness assessment test. During subsequent tests, the same subject profile can be loaded and data can be easily compared. This feature provides a convenient and simple way to track progress over time.

Quick Flow Calibration

Guided Flow calibration procedure wizard, walks you through the calibration procedure. 

Gas Calibration

Use the guided calibration procedure to calibrate the gas analyzer.  The iWorx gas analyzer measure both O2 and CO2 concentrations. A 12% O2 and a 5% CO2 gas mixture is recommended for the calibration gas.

Protocol Selection

Use one of the many preset protocols or create your own. 

When a protocol is run, the protocol will mark the record with the changes, such as speed or grade changes with a treadmill.

Control Exercise Equipment

Using the optional LS-ME metabolic Exercise equipment control module for LabScribe the following equipment can controlled from LabScribe

  • Treadmills: Treadmill that support the Trackmaster Protocol, such as treadmills from Trackmaster, Woodway 
  • Ergometers : Ergometers supporting the ANT+ FEC Trainer protocol.
  • Lode Ergometer: Lode Ergometers

Test

Various Metabolic test can be performed from a Resting metabolic rate (RMR) test to a VO2Max test.  The iWorx Gas analyzer records both O2 and CO2 concentrations.  The following parameters can be measured:

  • Abs.VO2 : Volume of Oxygen in Liters consumed per minute
  • Abs.VCO2: Volume of Carbon-dioxide in Liters produced per minute
  • Rel.VO2: Volume of Oxygen in ml consumed per minute per Kg of body weight
  • Rel.VCO2: Volume of Carbon-dioxide in ml produced per minute per Kg of body weight
  • RER: Respiratory exchange ratio.
  • REE (kcal/24hr)
  • METS
  • VE: Expired Volume per minute in BTPS
  • Watts: Energy expended
  • HR: Heart Rate

Data Analysis

The Metabolic Calculations Module also allows these parameters to be plotted against time or each other to yield valuable information about the aerobic fitness of the subject. These plots include:

  • VO2, VCO2, RER vs. Time
  • VCO2 vs. VO2
  • VE vs. VO2
  • VE vs. VCO2
  • HR, VCO2 vs. VO2
  • %Fat
  • VE vs. Watts
  • HR, VO2/HR vs. Watts
  • VO2, VCO2 vs. Watts
  • VE/VO2, VE/VCO2 Vs. Watts
  • Resting Energy Expenditure (REE)

Customizable report generator simplifies the task of creating a metabolic report. 

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Invasive BP : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type

Recover Password

We will contact you with your login info. 

Newsletter Signup