LabScribe ECG Analysis Module

The ECG Analysis Module is an add-on that enhances LabScribe with advanced tools for examining cardiac electrical activity. It automatically detects key ECG features, measures heart rate, intervals, and amplitudes, and provides options for beat-to-beat analysis and cycle averaging.

SKU: LS-ECG Category: Tags: , ,

Measurements

Templates for Different Species

Create your own custom template or use one of the templates provided for Human, Mouse, Rat, Rabbit, Pig, Guinea Pig, Small Dog, Large Dog, or Zebrafish. 

Use FIR and Notch filters to filter out the noise from the ECG signal before processing. 

Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval. See tips for reducing noise here.

The following locations are displayed on the ECG waveform:

  • Beginning, peak and end of P
  • Beginning of Q
  • Peak of R wave
  • End of S
  • Beginning, peak, and end of T wave
  • Calculates: Heart Rate, HRV Power bands
  • Intervals: Time @R, QRS, QT, QTc, QR, ST, Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R, Te-Tp, R-R, Delta R-R
  • Amplitudes: P, Q, R, S, T, ST elevation, QR Amp, IsoElectric Amp
  • Durations: T Duration, P Duration, TP Duration, QAT, QATN

Outlier removal based on abnormal R-R intervals, heart rate, noise, activity, P amplitude, and T amplitude.

Manually mark outliers if needed. A list of outliers is displayed in the Outliers tab.

Export a table of the measurements to excel for further analysis. Graphs can also be exported, along with the points used to draw the average graph. The average graph can be redrawn in any graphics program for publication.

Kubios HRV – Heart Rate Variability Analysis Software is an advanced tool for studying the variability of heart beat intervals. Data can be exported from LabScribe using the edf export option and then imported into Kubios HRV for analysis, as shown in this technote.

Manual

 

The Complete LabScribe manual can be found by navigating to the LabScribe toolbar and selecting “Help” > “Help (Manual)”

Tutorial Videos

Features

Templates for Different Species

Create your own custom template or use one of the templates provided for Human, Mouse, Rat, Rabbit, Pig, Guinea Pig, Small Dog, Large Dog, and Zebrafish. 

Filtering and Averaging

Use FIR and Notch filters to filter out the noise from the ECG signal before processing. 

Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval.

Graphical Display of Detected Points

The following locations are displayed on the ECG waveform:

  • Beginning, peak and end of P
  • Beginning of Q
  • peak of R wave
  • End of S
  • Beginning, peak and end of T wave

Measurements

  • Measure various intervals such as: QRS, QT, QTc, QR, ST Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R
  • Amplitudes such as: P , Q, R, S , T, ST elevation, QR Amp.
  • Durations such as : T Duration,  P Duration, TP Duration, QATN

Outliers and Artifacts

Outlier removal based on abnormal R-R intervals, heart rate, noise,  activity, P amplitude, and T amplitude.

Manually mark outliers if needed.  A list of outliers is displayed 

Compatibility

Plug and play compatible with all iWorx data acquisition. Measurements from surface, subcutaneous, and intracardiac electrodes. Use iWorx bio Amplifiers for a clean signal or use the optional Text Import module to analyze data recorded with other applications.

Software Updates

Software updates are free for iWorx customers.

Data Output

Export a table of the measurements to excel for further analysis. Graphs can also be export, along with the points used to draw the average graph, so that the average graph can be redrawn in any graphics program for publication

Features

Templates for Different Species

Create your own custom template or use one of the templates provided for Human, Mouse, Rat, Rabbit, Pig, Guinea Pig, Small Dog, Large Dog, and Zebrafish. 

Filtering and Averaging

Use FIR and Notch filters to filter out the noise from the ECG signal before processing. 

Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval.

Graphical Display of Detected Points

The following locations are displayed on the ECG waveform:

  • Beginning, peak and end of P
  • Beginning of Q
  • peak of R wave
  • End of S
  • Beginning, peak and end of T wave

Measurements

  • Measure various intervals such as: QRS, QT, QTc, QR, ST Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R
  • Amplitudes such as: P , Q, R, S , T, ST elevation, QR Amp.
  • Durations such as : T Duration,  P Duration, TP Duration, QATN

Outliers and Artifacts

Outlier removal based on abnormal R-R intervals, heart rate, noise,  activity, P amplitude, and T amplitude.

Manually mark outliers if needed.  A list of outliers is displayed 

Compatibility

Plug and play compatible with all iWorx data acquisition. Measurements from surface, subcutaneous, and intracardiac electrodes. Use iWorx bio Amplifiers for a clean signal or use the optional Text Import module to analyze data recorded with other applications.

Software Updates

Software upgrades are automatically available as they are released

Data Output

Export a table of the measurements to excel for further analysis. Graphs can also be export, along with the points used to draw the average graph, so that the average graph can be redrawn in any graphics program for publication

Manual

Videos

LabScribe ECG Analysis
ECG Analysis Window
ECG Artifact Detection
Arrhythmia Detection
ECG points marked on the graph in LabScribe
ECG points marked

Other LabScribe Features for ECG analysis

ECG Features in LabScribe

  • Calculate Heart Rate,
  • Export RR intervals
  • Calculate Lead III, aVr, aVf and aVl from Lead I and Lead II
  • Calculate HRV Power bands
  • Use Macros to automate tasks

Heart Rate Variability

Kubios HRV – Heart Rate Variability Analysis Software is an advanced tool for studying the variability of heart beat intervals.  Data can be exported from LabScribe using the edf export option and then imported into Kubios HRV for analysis, as shown in this technote

LabScribe Import Module

The iWorx ASCII Import Module enables import of data in text format that was recorded in any other data acquisition program. The module also allows the researcher to use the analysis functions in LabScribe software on data they may have previously recorded with a different program.

Have Questions?

The iWorx team is here to help—whether you have a quick question or need hands-on support. Our technical specialists offer one-on-one assistance with setup, troubleshooting, and optimizing your system.

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type

Recover Password

We will contact you with your login info. 

iWorx Newsletter Signup

By subscribing, you agree with our Privacy Policy and provide consent to receive updates from our company.