Search
Generic filters

ECG Simulator

A-ECG-SIM Multiparameter Simulator is a portable device providing comprehensive electrocardiogram (ECG/EKG) waveforms to the iWorx Recorders. It can be used as a training tool for distinguishing heart arrhythmias and monitoring cardiac function.

$795.00

SKU A-ECG-SIM Categories ,

A-ECG-SIM Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to the iWorx Recorders, it can be used as the training of distinguishing from arrhythmia waveforms to the student.

  • 3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
  • Display the output waveforms synchronously, which is convenient for user to compare with the   test equipment.
  • It integrates the functions of SD socket interface, user can output the custom waveform by this   device.
  • Built-in templates list to provide the waveform that is expressed by each preset sequence   number,which is convenient for searching.
  • Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
  • Optional external power: AC 220V, 50Hz or AC 120V, 60Hz
ECG/Arrhythmia

Conventional: All leads have the same voltage with the II-lead as the reference

  • Amplitude: 0.5,1.0,1.5 and 2.0mV
  • The accuracy of Amplitude: 2%
  • ECG Rate:
    • 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
  • ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
  • The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
  • The default: 80 BPM,1mV Arrhythmia
  • Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial
  • Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
  • Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min,
  • PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5
  • PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
  • Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left Ventricular Focus
  • PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early Right
  • Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right Ventricular Focus, Multifocal PVC
  • Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart   Block, Right Bundle Branch Block, Left Bundle Branch  Block
ECG Performance Testing
  • ECG amplitude:0.5, 1.0, 1.5 and 2.0mV
  • The accuracy of Amplitude: 2%
  • Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms
  • Square: 0.125 and 2.0 Hz
  • Triangle: 2.0 and 2.5 Hz
  • Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz
  • ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300,   320, 340 and 350 BPM
  • The accuracy of ECG Rate: 1%

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Invasive BP : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type