ECG Simulator

A-ECG-SIM Multiparameter Simulator is a portable device providing comprehensive electrocardiogram (ECG/EKG) waveforms to the iWorx Recorders. It can be used as a training tool for distinguishing heart arrhythmias and monitoring cardiac function.

$850.00


Manual: A-ECG-SIM

A-ECG-SIM Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to the iWorx Recorders, it can be used as the training of distinguishing from arrhythmia waveforms to the student.

  • 3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
  • Display the output waveforms synchronously, which is convenient for user to compare with the   test equipment.
  • It integrates the functions of SD socket interface, user can output the custom waveform by this   device.
  • Built-in templates list to provide the waveform that is expressed by each preset sequence   number,which is convenient for searching.
  • Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
  • Optional external power: AC 220V, 50Hz or AC 120V, 60Hz
ECG/Arrhythmia

Conventional: All leads have the same voltage with the II-lead as the reference

  • Amplitude: 0.5,1.0,1.5 and 2.0mV
  • The accuracy of Amplitude: 2%
  • ECG Rate:
    • 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
  • ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
  • The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
  • The default: 80 BPM,1mV Arrhythmia
  • Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial
  • Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
  • Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min,
  • PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5
  • PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
  • Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left Ventricular Focus
  • PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early Right
  • Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right Ventricular Focus, Multifocal PVC
  • Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart   Block, Right Bundle Branch Block, Left Bundle Branch  Block
ECG Performance Testing
  • ECG amplitude:0.5, 1.0, 1.5 and 2.0mV
  • The accuracy of Amplitude: 2%
  • Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms
  • Square: 0.125 and 2.0 Hz
  • Triangle: 2.0 and 2.5 Hz
  • Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz
  • ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300,   320, 340 and 350 BPM
  • The accuracy of ECG Rate: 1%

Have Questions?

The iWorx team is here to help—whether you have a quick question or need hands-on support. Our technical specialists offer one-on-one assistance with setup, troubleshooting, and optimizing your system.

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type

Recover Password

We will contact you with your login info. 

iWorx Newsletter Signup

By subscribing, you agree with our Privacy Policy and provide consent to receive updates from our company.