Pulse Oximeter Pro for Humans

The Pulse Oximeter and Plethysmograph Sensor measures blood oxygen saturation (SpO2) and pulse pressure (plethysmography) using a dual-wavelength light transmittance based finger clip.

Human pulse oximeter pro outputs the SPO2 and pulse waveform. Measure the Heart Rate using LabScribe software

Price range: $1,632.00 through $2,418.00

The Pulse Oximeter measures blood oxygen saturation (SpO2) in humans using a finger or ear clip sensor.

The USB pulse-ox is a stand alone device that comes with LabScribe software. It does not need an additional recorder.

The iWire pulse-ox requires an iWorx recorder with the iWire port, such as the IX-TA, IX-RA or IX-Peak recorders.

The DIN8 pulse-ox required an iWorx Recorder or amplifier with a DIN8 input and a BNC input ( for pulse signal).

 

Pulse Oximeter Specifications
O2 Saturation Range:80-100%
Pulse Rate Range:18 to 321 Beats per Minute (BPM)
SpO2 range80-100%
 Finger Clip:+2 digits
 Ear Clip:+3 digits
Measurement WavelengthRed – 660 nanometers Infrared – 925 nanometers
Temperature range0 – +50 degrees C
Humidity10 – 90% non-condensing
Power Draw60 mW – typical operating
Patient Isolation Dielectric WithstandMeets IEC 60601-1
Leakage Currentnot applicable
Integrated Finger sensor Dimension1.26 in. x 1.25 in. x 2 in. (32 mm x 32 mm x 51 mm)
Box Dimensions 2.27 in. x 2.4 in. x 1.0 in. 57 mm x 61 mm x 25 mm)
Units Conversion 80 % -> 0V 100% -> 2V ie Slope = 10, offset = 80

Pulse Ox sensor compatibility

iWire-PO2-200

Requires iWire port
  • IX-RA recorders
  • IX-TA recorders
  • IX-PEAK recorders
  • IX-400 recorders
  • Other BNC recorders
  • Powered by recorder

PO2-200D

Requires DIN and BNC inputs
  • IX-RA recorders
  • IX-TA recorders
  • IX-PEAK recorders
  • IX-400 recorders
  • Other BNC recorders
  • Powered by recorder

PO2-200B

Requires BNC inputs
  • IX-RA recorders
  • IX-TA recorders
  • IX-PEAK recorders
  • IX-400 recorders
  • Other BNC recorders
  • Powered by recorder

Compatible Sensors for the PO2-200 series

Have Questions?

The iWorx team is here to help—whether you have a quick question or need hands-on support. Our technical specialists offer one-on-one assistance with setup, troubleshooting, and optimizing your system.

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type

Recover Password

We will contact you with your login info. 

iWorx Newsletter Signup

By subscribing, you agree with our Privacy Policy and provide consent to receive updates from our company.