The EEG system consists of the IX-EEG recorder and the LabScribe acquisition and analysis software, including the EEG analysis module.
The IX-EEG is a 24 Channel Recorder for measuring 20 channels of EEG, two Bio Potential Channels, a GSR Channel and an Event Marker simultaneously from a single human subject.
$4,500.00 – $5,450.00
The EEG system consists of the IX-EEG recorder and the LabScribe acquisition and analysis software, including the EEG analysis module.
The IX-EEG is a 24 Channel Recorder allowing the following measurements simultaneously from a single human subject:
The EEG is recorded using a 10-20 system EEG cap with Silver-SilverChloride electrodes. The recorder is furnished with LabScribe Software with the EEG Analysis Module and connects directly to a USB port on either a Macintosh or Windows computer.? The EEG and GSR electrodes are connected to the subject by snap-leads to pre-gelled Ag/AgCl electrodes.
The IX-EEG requires an EEG cap such as : A-EEG-CAPSYS.
McLees, Sallie. The Effect of Bilingualism on Perceptual Processing in Adults. Diss. Arizona State University, 2019.
Bryant, Corey. The Neurodynamics of Working Memory during a Stress Induced State. University of Michigan-Dearborn, 2016.
Lima, Gabriel, and Fabiana Rocha. ‘Curiosity, Frontal EEG Asymmetry, and Learning.‘
Differential Anterior EEG Brain Activity While Viewing Violent or Neutral Video Clips
Patrick A. Ament, Adam Runyan, Michael J. Omerza, Taylor Rodieck, Amanda Fuller, Darby M. Simon, and Isaac Flint, University of Central Missouri, Department of Psychological Science
EEG: Frontal Pole Asymmetry and Video Game Addiction
Adam Runyan, Michael Omerza, Amanda Fuller, Taylor Rodieck, Darby Simon, Isaac Flint, Teigan Hockman, Patrick Ament
University of Central Missouri, Department of Psychological Science
Insight into the Before and After of Problem Solving using Event Related Potentials
Timothy Burnham, Samantha Oeser, Abigail Lamp & Joshua Halonen, Ph.D
Dept. of Psychology at Friends University
In addition to the LabExercises various ERP studies can also be performed with the IX-EEG such as:
Symbol Processing in the Blink of an Eye: an EEG Study :
by Isaiah Cushman, Gemma Francisco, Michelle Kang, and Nick Taylor, of Irvine Valley College
These are some additional Lab Exercises that you can perform with the IX-EEG.
Specifications | |
EEG Inputs | 20 Channels of EEG, using a
10-20 EEG cap (Ag-AgCl electrodes recommended) |
Bio-Potential | 2 channels for ECG, EMG, EOG etc |
GSR | 1 Channel ( requires C-ISO-GSRYB) |
Event Marker | 1 Channel ( requires EM-IXEEG) |
A/D Converter | |
Input Range | +/- 180mV |
Sampling Speed | 500 Samples/sec per channel simultaneous |
Resolution | 24 Bit |
System Noise | 1 uV p-p input shorted noise at
100 s/sec 2 uV p-p input shorted noise at 500 s/sec |
Input Impedance | >500 M Ohm |
CMRR | 110 dB |
Interface | USB |
Software | LabScribe3 with EEG Analysis Module |
Montages | Preset standard montages |
General | |
Enclosure | Plastic |
Power | USB |
Warranty and Upgrades | Protected by a 3 year warranty |
Optional Advanced ERP Analysis Module available.
We will contact you with your login info.