IX-400 4, 8, 16 Channel Single Ended Recorders

The iWorx 400 Series recorders are economical, high performance four, eight or sixteen channel data recorders for use with a broad range of analog amplifiers.? The recorders offer 16-bit resolution at a maximum data collection speed of 10 kHz,? making them appropriate for most research applications.

$2,350.00$5,995.00

Clear
SKU IX-400 Category Tag

Features

Resolution
The 400 series recorders use a 16-bit A/D converter to sample data over its full input range of +/-10V at speeds up to 10kHz. The low noise (<1mV) greatly reduces the need for gain and offset.

LabScribe Software Provides Powerful Analysis ToolsLabScribe Data Acquisition and Analysis
Installation and operation of the LabScribe acquisition and analysis software is easy and straightforward. LabScribe software allows ‘one-click’ control of the entire acquisition process, plus a large library of standard analytical functions to process data. The 400 series recorders are powered via a USB interface to any Macintosh or PC, eliminating the need to install special interface cards. Users are typically recording and analyzing signals within minutes of installation.It supports real units and a time based display that is not coupled to sample rate. The display can be configured to allow viewing of as many data points as the user desires. Scrolling, zoom-in and zoom-out tools, together with a searchable list
of user interventions, make finding important areas of data easy.

LabScribe provides a powerful array of built-in data analysis tools. It strikes a balance between the straightforward, general operations that everyone uses and the vertical, complex routines that only you use. The result is a powerful analytical tool that can go to work on your data right away, or be customized to do very specific and complex analyses.

Pressure Volume Loop Software Module
The iWorx Pressure Volume Loop Software Module is a plug-in software module foruse with iWorx data acquisition systems that performs pressure volume loop analysis for hemodynamic research in animals.? The software module provides a powerful and easy to use tool for investigators to measure and analyze the hemodynamic parameters of cardiac and pulmonary pressure and volume data acquired by an iWorx recorder.

Exceptional Value
The 400 series recorders provide turnkey continuous recording solutions at a fraction of the cost and complexity associated with systems requiring PCI bus plug-in cards. No breakout box is required, as connectors are part of the enclosure. In fact, no other hardware is required to get up and running.

Compatible Amplifiers and Sensors

iWorx Amplifiers compatible with the IX-400 series allow the use of most iWorx sensors.
IA-400D 4 channel signal conditionerIA-400D Transducer Amplifier
ETH-256 2 channel versatile signal conditioner
Sensors with a BNC output that plugin directly
PRH-200 Patellar Reflex Hammer with a BNC connectorPatella Reflex Hammer
PT-100 Pulse Plethysmograph (Piezo Crystal) with BNC connector
RM-200 Respiration Monitor (piezo crystal) with BNC Connector
RM-200A Respiration Monitor (piezo crystal) with BNC Connector (Animal)
PO2-100B Pulse Oximeter with BNC outputs – finger sensor included
System Requirements

LabScribe v4:

  • Windows OS: Vista, Win7, Win8, Win10
  • Mac OS: OSX 10.9 and above
  • Linux: ( beta testers required )

Computer hardware for LabScribe:

  • Minimum specs: Dual Core processor, 4GB or greater memory.
  • Recommended specs: Quad Core 64 bit Processor, 4GB or greater memory.

Specifications

Input
Analog Inputs4, 8 or 16
Input Impedance1M Ohm
Input Range+10 VDC
Noise<1mV
Stimulator Output408,416 only
Range+ 10V
Resolution16 bit
Speed10,000 simultaneously (404) 100,000 aggregate (408, 416)
Stimulation ProtocolsPulse, Train, Step, DC, Ramp, Triangle
Digital Input/Output
Digital Inputs4
Digital Outputs4
ConnectorDB9
General
EnclosurePlastic
InterfaceUSB
CertificationCE
Power5VDC 2.6A (IX-408 & IX-416) USB (IX-404)
Warranty and UpgradesProtected by a 3 year warranty
SoftwareLabScribe
Part NumbersIX-404, IX-408, IX-416
Datasheets: Manual: 4xx_manual

Design Your System

Choose the parameters you want to Measure

ECG/EKG
EMG : Number of Channels
Invasive BP : Number of Channels
Non-Invasive BP : Number of Channels
Flow : Number of Channels
Temperature: Number of Channels
Force: Number of Channels
Stimulation: Describe the type

Recover Password

We will contact you with your login info. 

Newsletter Signup