The UBIK-TR Ultimate BioInstrumentation Physiology Lab Kit includes all of the necessary hardware and components, LabScribe software and expertly written, customizable, courseware to teach 85 experiments and more than 200 exercises in biosensing cardiovascular, respiratory, and neuromuscular physiology. The UBIK-TR kit also allows the student to signal condition, biosignals acquired from biosensors.
Features
Wired ECG/EMG option available: UBIK-TRi
Information about previous generation: Ultimate BioInstrumentation Teaching Kit
Software
Circuit Design
Students can create experiments and study design of add-on circuits using the breadboard. Signal from any input channel of the IX-TA-ROAM can be routed to the stimulator and sent to the breadboard using the C-BNC-BB cable. Students have the ability to design a custom circuit to condition the signal. The conditioned signal can then be sent back to the IX-TA-ROAM using the C-DIN-BB cable, allowing the student to compare the raw biosignal and the conditioned signal in LabScribe.
Stimulator
The Stimulator in the IX-TA-ROAM can be setup to output waveforms, such as a square wave, sine wave (up to 1kHz), pulses, steps, trains as well as custom waveforms. Create a custom waveform in Excel and paste it into the custom waveform generator to output a custom waveform. The stimulator feedback channel allows the user to see the stimulator output. Stimulator toolbar allows changes to the protocol during recording.
Digital i/o
16 digital inputs/output are available. The digital output can be preset to output a pattern, just like the stimulator.


LabScribe Data acquisition and analysis software

Analyze action potentials data with LabScribe

4 channel biopotential module for recording EMG, ECG and other biopotentials

C-ISO-PN5: set of 5 platinum needle electrodes

Stimulator Cable – BNC to Dual Platinum needle electrodes

Set of Two Platinum Subdermal Electrodes with High Voltage Safety Connectors

5k Force Transducer, laser interrupt sensors, Magnetic Field Sensor,

Conductivity Sensor, Colorimeter and Turbidity Sensor, Drop Counter, Humidity Sensor, Dissolved Oxygen Electrode, Ph Electrode

Force Transducer, Nerve Bath Chamber, O2 Electrode, platinum stimulating and recording electrodes

Force Transducer, Nerve Bath Chamber, platinum stimulating and recording electrodes, Flexible Silver Wire Electrodes, Dissection Kit

O2/CO2 Analyzer, 1000L Flow Head, Re-Usable Head Gear and Face Mask, Non-Re-Breathing Valve Assembly, 5 L Mixing Chamber, Clean Bore Tubing, Scosche HR

pH Probe, Conductivity Meter, O2 Electrode, Respiration/Photosynthesis Chamber, Osmosis and Diffusion Chamber

4 button Response pad, Bi-Color Light Source, Foot Reaction Switch

Intracellular Probe , Nerve Bath Chamber, Suction Electrode, Hook Electrode, Needle Electrodes, Suction Electrode, Reflex Hammer, Goniometer, Flexible Silver Wire Electrodes

Includes NMD-EAR, NMD-EYE and Spike Sorting Analysis Module
Use a stimulus channel to mark the onset of the stimulus, identify the start and stop of the peak, and measure the latency to the start of the peak and to the peak maximum.
Calculations include:

Software
LabScribe is a powerful recording and analysis software package developed by iWorx. LabScribe has an intuitive, user-friendly interface for setting up acquisition screens, calibrating signals and analyzing data.
iWorx API: Custom applications can be developed for iWorx Hardware using our API. MATLAB and LabView can be used to record data from iWorx recorders.
Circuit Design
Students can create experiments and study design of add-on circuits using the breadboard. Signal from any input channel of the IX-TA-ROAM can be routed to the stimulator and sent to the breadboard using the C-BNC-BB cable. Students have the ability to design a custom circuit to condition the signal. The conditioned signal can then be sent back to the IX-TA-ROAM using the C-DIN-BB cable, allowing the student to compare the raw biosignal and the conditioned signal in LabScribe.
Stimulator
The Stimulator in the IX-TA-ROAM can be setup to output waveforms, such as a square wave, sine wave ( up to 1kHz), pulses, steps, trains as well as custom waveforms. Create a custom waveform in Excel and paste it into the custom waveform generator, to output a custom waveform. Stimulator feedback channel allows the user to see the stimulator output. Stimulator toolbar allows changes to the protocol during recording.
Digital i/o
16 digital inputs/output are available. The Digital output can be preset to output a pattern, just like the stimulator.
Martinovic, Ivan, and Vesna Mandic. ‘Biomedical Signals Reconstruction Under the Compressive Sensing Approach.’?arXiv preprint arXiv:1802.00337?(2018).

5k Force Transducer, laser interrupt sensors, Magnetic Field Sensor,

Conductivity Sensor, Colorimeter and Turbidity Sensor, Drop Counter, Humidity Sensor, Dissolved Oxygen Electrode, Ph Electrode

Force Transducer, Nerve Bath Chamber, O2 Electrode, platinum stimulating and recording electrodes

Force Transducer, Nerve Bath Chamber, platinum stimulating and recording electrodes, Flexible Silver Wire Electrodes, Dissection Kit

O2/CO2 Analyzer, 1000L Flow Head, Re-Usable Head Gear and Face Mask, Non-Re-Breathing Valve Assembly, 5 L Mixing Chamber, Clean Bore Tubing, Scosche HR

pH Probe, Conductivity Meter, O2 Electrode, Respiration/Photosynthesis Chamber, Osmosis and Diffusion Chamber

4 button Response pad, Bi-Color Light Source, Foot Reaction Switch

Intracellular Probe , Nerve Bath Chamber, Suction Electrode, Hook Electrode, Needle Electrodes, Suction Electrode, Reflex Hammer, Goniometer, Flexible Silver Wire Electrodes

Includes NMD-EAR, NMD-EYE and Spike Sorting Analysis Module
Quick online consultation with an Applications Specialist
We will contact you with your login info.
By subscribing, you agree with our Privacy Policy and provide consent to receive updates from our company.